CCSST - CHEMIGUM TWO PART CEMENT 1895C, 1492C BASE

  • MSDS: CCSST
  • Manufacturer: ENGINEERED FABRICS CORP
  • Product Name: CHEMIGUM TWO PART CEMENT 1895C, 1492C BASE
  • National Stock Number: 8040-00-439-3696
Product Identification

Product ID:CHEMIGUM TWO PART CEMENT 1895C, 1492C BASE
MSDS Date:09/01/1993
FSC:8040
NIIN:00-439-3696
Kit Part:Y
MSDS Number: CCSST

Responsible Party
ENGINEERED FABRICS CORP
669 GOODYEAR ST
ROCKMART, GA 30153
US

Emergency Phone: 216-379-8562;800-424-9300(CHEMTREC)

Info Phone: 770-684-7855

Preparer: WILLIAM RITTER

Cage: 0KDP8

Contractor
ENGINEERED FABRICS CORPORATION
548 ROCKMART, GA 30153 US

Telephone: 706-684-7855

Cage: 56221

Ingredients

2-BUTANONE; (METHYL ETHYL KETONE) (SARA 313) (CERCLA)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 80-85%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM; 300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONTACT WITH THE EYE CAN CAUSE
SEVERE IRRITATION, REDNESS, TEARING AND BLURRED VISION. EXCESSIVE
INHALATION OF VAPORS CAN CAUSE NASAL AND RESPIRATORY IRRITATION,
DIZZINESS, WEAKNESS, FATIGUE, N AUSEA, HEADACHE, POSSIBLE
UNCONSCIOUSNESS AND EVEN ASPHYXIATION. CHRONIC: PROLONGED OR
REPEATED (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CONTACT WITH THE SKIN CAN CAUSE
MODERATE IRRITATION, DEFATTING AND DERMATITIS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: IF AFFECTED, REMOVE TO FRESH AIR. IF BRTHG IS DFCLT,
ADMIN OXYGEN. IF BRTHG HAS STOPPED, GIVE ARTF RESP. KEEP PERSON
WARM, QUIET & GET MED ATTN. EYES: FLUSH EYES W/LG AMTS OF WATER,
LIFTING UPP ER & LOWER LIDS OCCAS. GET MED ATTN. SKIN: THOROUGHLY
WASH EXPOSED AREA W/SOAP & WATER. REMOVE CONTAMD CLTHG. LAUNDER
CONTAMD CLTHG BEFORE REUSE. INGEST: GIVE TWO GLASSES OF WATER.
INDUCE (SUPDAT)

Fire Fighting

Flash Point Method:CC
Flash Point:16.0F,-8.9C
Lower Limits:1.4% @ 200F
Upper Limits:11.4% @ 200F
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
ALONG THE GROUND OR MAY BE MOVED BY VENTILATION AND BE IGNITED AT
LOCATIONS DISTANT FROM THE MATERIAL HANDLING POINT.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNIT SOURCES. VENT AREA. WEAR
PERSONAL PROT EQUIP AS NEC. DIKE OR CONTAIN SPILL W/ABSORB OR OTHER
AVAIL MATLS. DO NOT ALLOW SPILL TO DISCHARGE INTO STORM OR SANITARY
SEWER. PUMP OR BAIL MA TL BACK INTO ORIGINAL CNTNR OR CLEAN,
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:THE STORAGE AREA SHULD BE WELL
VENTILATED. STORE AWAY FROM SOURCES OF HEAT AND OPEN FLAMES. KEEP
CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:WARNING! FLAMMABLE LIQUID. KEEP AWAY FROM HEAT AND
OPEN FLAMES. NEVER USE WELDING OR CUTTING TORCHES ON OR NEAR EVEN
EMPTY CONTAINERS AS JUST PRODUCT RESIDUE CAN IGNITE EXPLOSIVELY.

Exposure Controls

Respiratory Protection:IF WORKPLACE CONCENTRATIONS EXCEED THE
RECOMMENDED TLVS, USE NIOSH APPROVED RESPIRATOR TO PREVENT
OVEREXPOSURE. I/A/W 29 CFR 1910.134 USE EITHER AN
ATMOSPHERE-SUPPLYING RESPIRATOR OR AN AIR-PURIFYING RESPIRATOR FOR
ORGANIC VAPORS.
Ventilation:PROVIDE ADEQUATE, EXPLOSION-PROOF VENTILATION TO MAINTAIN
VAPORS BELOW THE TLV LISTED IN INGREDIENT SECTION.
Protective Gloves:BUTYL GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
WEAR IMPERVIOUS PROTECTIVE CLOTHING TO PREVENT SKIN CONTACT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN.
Supplemental Safety and Health
FIRST AID PROC: VOMIT IMMED BY STICKING FINGER DOWN THROAT. CALL MD.
NEVER GIVE ANYTHING BY MOUTH TO UNCON PERSON. SPILL PROC: EMPTY
CNTNR OF SAME DOT SPECIFICATION. ALL MATLS USED IN CLEAN UP PROCESS
& THAT ARE SUBSEQUENTLY TO BE DISCARDED ARE CONSIDERED HAZ WASTE.
EPA RCRA ID NUMBER:D001, F005. REFERENCE 40 CFR 261.

Chemical Properties

Spec Gravity:0.86
Appearance and Odor:BLACK LIQUID; SOLVENT ODOR.
Percent Volatiles by Volume:85

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS
AND REGULATIONS APPLICABLE TO PACKAGING, MANIFESTING, TRANSPORTING
AND DISPOSING OF HAZARDOUS WASTE. INCINERATE AT A FACILITY LICENSED
FOR DISPOSAL OF IGN ITABLE HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.